Top-Rank Trade co.,Ltd

 

Light Commercial Air conditioner

Fan Coil

 


SPECIFICATIONS

2 PIPES WATER CASSETE UNITS ? PCE SERIES SPECIFICATIONS:
Model PCE-03 PCE-04 PCE-06 PCE-08 PCE-09 PCE-10 PCE-12 PCE-16
Number Of Fan Blowers Single Single Single Single Twin Twin Twin Twin
Nominal Airflow H m3/min 7.5 8.5 10.4 12.8 17 19.3 21.4 25
M 6.6 7 9.4 10.4 14 16 18.5 21
L 5.6 5.8 7.8 8.6 11.5 13 15.5 17.5
Nominal Cooling Capacity* H KW 2.52 3.11 4.05 4.98 6.7 7.68 8 9.04
M 2.25 2.6 3.4 4.2 5.67 6.48 6.78 7.71
L 2.1 2.21 2.9 3.52 4.8 5.35 5.77 6.52
Nominal Sensible Cooling Capacity H KW 2.03 2.17 2.84 3.17 4.7 5.2 5.38 6.3
M 1.79 1.92 2.51 2.84 4.04 4.48 4.73 5.6
L 1.67 1.67 2.19 2.47 3.48 3.9 4.2 4.92
Nominal Heating Capacity** H KW 5.76 6.18 8.21 9.66 13.2 14.66 15.9 17.1
M 5.15 5.45 7.13 8.15 11.48 12.68 13.65 15.04
L 4.8 4.7 6.2 7.01 9.85 10.98 12.1 13.2
Nominal Heating Capacity*** H KW 3.03 3.29 4.29 5.02 7.05 7.8 8.32 8.9
M 2.71 2.84 3.73 4.25 6.1 6.75 7.21 7.9
L 2.52 2.5 3.24 3.69 5.25 5.8 6.37 6.95
Noise Level at 1 m(L/M/H) dB(A) 34/36/38 35/37/39 39/41/43 42/44/46 36/38/40 41/43/46 44/46/49 46/49/52
Power Supply 230V/1PHASE/50HZ
Fan Motor Power Watt 26 31.7 58 61.1 63.4 116 116 124
Fan Motor Running Current Amp. 0.113 0.146 0.253 0.264 0.292 0.506 0.528 0.584
Fan Motor Starting Current Amp. 0.34 0.438 0.759 0.792 0.876 1.52 1.59 1.752
Operation Control & Thermostat Remote Controller and wiring controller
Water Flow Rate 1/h 480 587 765 940 1265 1450 1510 1707
Water Pressure Drop KPa 7.0 10.2 9.6 13.9 22.5 24.9 12.4 15.4
Water Content 1 1.3 1.3 1.79 1.79 1.47 2.84 2.84 2.84
Cond. Drain Connection I.D. mm (inch) 19.05(3/4V)
Casing Dimensions L mm 570 570 570 570 1100 1100 1100 1100
W mm 570 570 570 570 570 570 570 570
D mm 250 250 290 290 290 290 290 290
Panel Dimensions mm 650~650~28 690~1220~28
Gross Weight kgs 28 28 31 31 57 59 59 59
Connection Method   Socket(Threaded Female)
Water Connection In mm (inch) 19.05(3/4V)
Out mm (inch) 19.05(3/4V)

Cooling *:27C db/19.5C wb entering air temperature,7C entering water and 12C leaving water temperature.

Heating**:20C db entering air temperature ,70C entering water with water flow rate the same as for the cooling test (Under Eurovent testing requirement).

Heating***:20C db entering air temperature, 50C entering water with water flow rate the same as for the cooling test (Under Eurovent testing requirement).

2 PIPES WATER CASSETE UNITS ? PCF SERIES SPECIFICATIONS:

Model PCF-09 PCF -10 PCF -12 PCF -16 PCF -18 PCF-20
Number Of Fan Blowers Single Single Single Single Single Single
Nominal Airflow H m3/min 14.2 17 22.67 28.33 34 39.67
M 10.8 13 17.5 21.83 26.17 30.5
L 8.3 10 13.33 16.83 20.17 23.5
Nominal Cooling Capacity* H KW 5.42 6.32 8.17 10.05 11.68 13.4
M 4.21 5.0 6.5 7.88 9.28 10.65
L 3.29 3.9 5.02 6.27 7.29 8.47
Nominal Sensible Cooling Capacity H KW 3.74 4.21 4.99 6.52 7.26 7.97
M 3.12 3.51 4.25 5.49 6.19 6.77
L 2.44 2.91 3.54 4.63 5.21 5.76
Nominal Heating Capacity** H KW 10.6 12.05 14.7 19.1 21.68 24.08
M 8.55 9.93 12.25 15.86 18.04 20.05
L 7.13 8.18 10.1 13.15 15 16.7
Nominal Heating Capacity*** H KW 5.54 6.31 7.71 9.97 11.29 12.48
M 4.55 5.2 6.45 8.3 9.4 10.49
L 3.75 4.3 5.3 6.85 7.84 8.72
Noise Level at 1 m(H/M/L) dB(A) 42/39/37 45/42/39 53/49/46 54/51/48 55/51/45 59/53/47
Power Supply 230V/1PHASE/50HZ
Fan Motor Power Watt 70.2 80.5 100 150 192 241
Fan Motor Running Current Amp. 0.305 0.367 0.435 0.652 0.844 1.079
Fan Motor Starting Current Amp. 0.915 1.1 1.31 1.956 2.532 3.237
Operation Control & Thermostat Remote Controller and wiring controller
Water Flow Rate 1/h 1023 1193 1543 1898 2205 2530
Water Pressure Drop KPa 12.1 15.6 24.8 14.23 18.65 23.9
Water Content 1 2.531 2.531 2.531 3.625 3.625 3.625
Cond. Drain Connection I.D. mm (inch) 19.05(3/4V)
Casing Dimensions L mm 730 730 730 930 930 930
W mm 730 730 730 930 930 930
D mm 290 290 290 290 290 290
Panel Dimensions mm 850~850~28 1050~1050~28
Gross Weight kgs 42 42 42 60 60 60
Connection Method   Socket(Threaded Female)
Water Connection In mm (inch) 19.05(3/4V)
Out mm (inch) 19.05(3/4V)

Cooling *:27C db/19.5C wb entering air temperature,7C entering water and 12C leaving water temperature.

Heating**:20C db entering air temperature ,70C entering water with water flow rate the same as for the cooling test (Under Eurovent testing requirement).

Heating***:20C db entering air temperature, 50C entering water with water flow rate the same as for the cooling test (Under Eurovent testing requirement).